Areas of application include building base isolation, isolation of machines and equipment, structure borne noise created by activities like people moving, dishwashers, washing machines and electronic devices, particularly in multi-storey wooden buildings. By integrating vibration insulation with Regufoam, these disturbances can be reduced.

Product Characteristics

Continuous static load
0.85 N/mm²

Continuous and variable loads/operating load range
0 to 1.20 N/mm²

Peak loads (rare, short-term loads)
up to 7 N/mm²

Standard forms of delivery, ex warehouse

Sheets
Thickness: 12.5 and 25 mm are standard, and regularly available off the shelf. Special thicknesses on request
Length: 1500 mm, special lengths available on request
Width: 1000 mm

Strips or pads
On request: Die-cutting, water-jet cutting, self-adhesive versions possible

On request we can tailer to your needs and produce 75, 50, 37.5, 25, 12.5, 6 mm all the way down to 2 mm thicknesses.

Technical Specifications

regufoam-810-specifications.xlsx

Regufoam 810

Physical property Norm Result Comment
Static modulus of elasticity Based on EN 826 5.4 - 8.0 N/mm2 Tangential modulus, see figure “modulus of elasticity”
Dynamic modulus of elasticity Based on DIN 53513 11.0 - 16.5 N/mm2 Depending on frequency, load and thickness, see fi gure “dynamic stiffness“
Mechanical loss factor DIN 53513 0.10 Load-, amplitude- and frequency-dependent
Compression set Based on DIN EN ISO 1856 7.9 % Measured 30 minutes after decompression with 50 % deformation / 23 °C after 72 hrs
Tensile strength Based on DIN EN ISO 1798 4.6 N/mm2
Elongation at break Based on DIN EN ISO 1798 230%
Tear resistance Based on DIN ISO 34-1 20.0 N/mm
Fire behaviour DIN 4102 B2
DIN EN 13501-1 E
Sliding friction REGUPOL-laboratory 0.6 Steel (dry)
REGUPOL-laboratory 0.75 Concrete (dry)
Compression hardness Based on DIN EN ISO 3386-2 1241 kPa Compressive stress at 25 % deformation test specimen h = 25 mm
Rebound elasticity Based on DIN EN ISO 8307 58% dependent on thickness, test specimen h = 25 mm
Force reduction DIN EN 14904 35% dependent on thickness, test specimen h = 25 mm