Bulkhead Penetration VT-BHP
Vibratec provides a series of watertight bulkhead penetrations. They are delivered as complete sets, with no need for drilling or burning through plates.
All you need to do is to burn a hole in the bulkhead, lead the pipes through and fix by welding. When leading exhaust pipes through bulkheads, direct Contact must be avoided, to prevent transfer of heat and vibrations (noise) to the construction. This can be safely done by applying bulkhead penetrations of type BHP.
In somewhat adapted from these lead-troughs can be applied to stationary situations, like buildings, as well.
Our deck and bulkhead penetrations permit free extension of pipes and limit noise transfer to minimum values. By applying lagging temperature transfer to the construction is minimized as well.
Product Characteristics
Installation
Mounting bulkhead penetrations is extremely simple, all you have to do is burn a hole in the bulkhead according to the sizes on the below chart.
Remove the gasket, insulation ring and rubber rings before welding!
Technical Specifications
bulkhead-penetration-vt-bhc-technical-specifications.xlsx
Dimensions
NB | øA | øB | øC | øD | øE | F | ø Opening in bulkhead |
(mm) | (mm) | (mm) | (mm) | (mm) | (mm) | ||
050 | 60.3 | 160 | 200 | 240 | 300 | 8 | 220 |
065 | 76.1 | 160 | 200 | 240 | 300 | 8 | 246 |
080 | 88.9 | 160 | 200 | 240 | 300 | 8 | 274 |
100 | 114.3 | 230 | 270 | 310 | 370 | 8 | 300 |
125 | 139.7 | 230 | 270 | 310 | 370 | 8 | 336 |
150 | 168.3 | 230 | 270 | 310 | 370 | 8 | 390 |
200 | 219.1 | 320 | 370 | 420 | 480 | 8 | 450 |
250 | 273.0 | 370 | 420 | 470 | 530 | 8 | 482 |
300 | 323.9 | 445 | 495 | 545 | 605 | 12 | 406 |
350 | 355.6 | 445 | 495 | 545 | 605 | 12 | 437 |
400 | 406.4 | 500 | 550 | 600 | 660 | 12 | 468 |
450 | 457.2 | 550 | 600 | 650 | 710 | 12 | 529 |
500 | 506.0 | 600 | 650 | 700 | 760 | 12 | 590 |
Other dimensions on request |